Autoclave Manufacturer, Suppliers and Exporter in Delhi India

Eduscope India is a leading Autoclave Manufacturer,and suppliers in Delhi India

EduScope India's Autoclave range covers steam sterilization equipment for school, college and clinical teaching laboratories — three benchtop portable units and four floor-standing vertical and horizontal models, manufactured and supplied as part of the company's wider Laboratory Appliances line for TVET institutes, universities and research facilities.

Portable, vertical or horizontal — which autoclave format fits your lab?

The three portable models — Portable, Stainless Steel, Wing Nut Type, Portable, Aluminium, Pressure Cooker and Portable, Stainless Steel, Pressure Cooker Type — are single-wall, lid-clamped units sized for a benchtop, each fitted with a pressure gauge, double safety valve, steam and vacuum release valves and a mild steel stand.

The vertical models step up to a double or triple wall for better heat retention: Vertical, Stainless Steel, Nut Locking uses a threaded nut to seal the lid, while Vertical, Double Walled, Radial Locking and Triple Wall, Vertical, High Pressure seal instead through radial locking arms turned by a central steering-wheel handle — faster to open and close on a larger chamber. These three models run at 5 to 20 psi, the standard steam-sterilization pressure band; at the top of that range, 15–20 psi, saturated steam sits at approximately 121–126°C, the industry-standard autoclave sterilization temperature. The Triple Wall unit adds a digital timer, digital temperature readout, pressure control switch, low-water cut-off and an alarm/buzzer for supervised, higher-throughput runs.

The Horizontal, Cylindrical, Double Wall model is the largest-format unit in the range — floor-mounted on a tubular steel frame with levelling screws, radial-locked, operating at 15–20 psi (approximately 121–126°C saturated steam), and carrying the same digital timer, digital temperature, low-water cut-off and buzzer controls as the Triple Wall vertical.

Autoclave range at a glance

ModelFormatWall / lid constructionLocking typeOperating pressureControls fitted
Portable, SS, Wing Nut TypePortableSingle wall — SS shell, aluminium ring, SS/aluminium lidWing nutBenchtop pressure-cooker cyclePressure gauge, double safety valve, steam & vacuum release valves
Portable, Aluminium, Pressure CookerPortableSingle wall — aluminiumPressure-cooker lidBenchtop pressure-cooker cycleSame core valve set; epoxy powder coating available on request
Portable, SS, Pressure Cooker TypePortableSingle wall — stainless steelPressure-cooker lidBenchtop pressure-cooker cycleSame core valve set
Vertical, SS, Nut LockingVerticalDouble wall — SS chamber, outer wall, lid and ringNut locking5–20 psi (~121–126°C at 15–20 psi)Leak-proof double-wall chamber
Vertical, Double Walled, Radial LockingVerticalDouble wall — SS chamber & outer wall, SS/MS ringRadial arm (steering-wheel)5–20 psi (~121–126°C at 15–20 psi)SS bucket, mild steel legs
Triple Wall, Vertical, High PressureVerticalTriple wall, double chamber — SSRadial arm (steering-wheel)5–20 psi (~121–126°C at 15–20 psi)Digital timer, digital temperature, pressure control switch, low-water cut-off, alarm
Horizontal, Cylindrical, Double WallHorizontalDouble wall — SS inner chamber, outer cover, lidRadial locking, chrome-plated MS15–20 psi (~121–126°C)Digital timer, digital temperature, low-water cut-off, buzzer, tubular steel frame

Related ranges

Laboratory Appliances · Laboratory Balances · Centrifuge · Colorimeter · Heating Mantle · Laboratory Water Bath · Laboratory Equipment · Burners · Clinical Laboratory · Cold Chain Equipment · All Products · Frequently Asked Questions

Frequently asked questions

What's the difference between the portable and vertical autoclaves in this range?

The three portable models are single-wall, lid-clamped units sized for a benchtop. The vertical and horizontal models add a double or triple wall, nut or radial locking, and — on the Triple Wall and Horizontal units — digital timer and temperature controls for higher-throughput sterilization runs.

What pressure and temperature do the vertical and horizontal autoclaves run at?

EduScope India's Vertical, Triple Wall and Horizontal autoclaves operate across 5 to 20 psi, the standard steam-sterilization pressure band. At the top of that range — 15–20 psi — saturated steam sits at approximately 121–126°C, the industry-standard autoclave sterilization temperature.

How do I get the chamber capacity for a specific model?

Chamber capacity is available on request — share the batch size or item count you need to sterilize via Contact Us and EduScope India will match it to a model.

What's the difference between nut locking and radial locking?

Nut locking seals the lid with a threaded ring, turned by hand. Radial locking uses arms driven by a central steering-wheel handle, which is typically faster to open and close on the larger Double Walled, Triple Wall and Horizontal models.

Can these autoclaves be supplied against a government or institutional tender?

Yes. EduScope India prepares itemised quotations against a bill of quantities and supports a Manufacturer's Authorisation Form, technical datasheets, Certificate of Origin, packing lists and HS codes. Submit specifications via the Tenders/OEM page.

Can an autoclave be quoted alongside other Laboratory Appliances, like balances or centrifuges?

Yes. Submit your autoclave requirement together with Laboratory Balances, Centrifuge or any other Laboratory Appliances subcategory via Contact Us for one consolidated quotation.

Request a quote or catalogue

Send EduScope India the autoclave format, quantity and delivery destination you need, via Contact Us, request tender documentation via the Tenders/OEM page, or browse the full Product Catalogue.

Autoclave, Portable, Stainless Steel, Wing Nut Type

Autoclave, Portable, Stainless Steel, Wing Nut Type

Product Code : EL-A-12629

Autoclave, Portable, Stainless Steel, Wing Nut Type — a compact, wing-nut-sealed bench-top pressure sterilizer with a stainless steel shell, aluminium ring, and a stainless steel and aluminium lid, rated 5–20 psi.

View Details
Autoclave, Portable, Aluminium, Pressure Cooker

Autoclave, Portable, Aluminium, Pressure Cooker

Product Code : EL-A-12630

Autoclave, Portable, Aluminium, Pressure Cooker — a compact, screw-down bench-top pressure sterilizer with an aluminium shell, rated 5-20 psi, also available with epoxy powder coating.

View Details
Autoclave, Portable, Stainless Steel, Pressure Cooker Type

Autoclave, Portable, Stainless Steel, Pressure Cooker Type

Product Code : EL-A-12631

Autoclave, Portable, Stainless Steel, Pressure Cooker Type — a compact, screw-down bench-top pressure sterilizer built in stainless steel, rated 5-20 psi (roughly 109-126°C).

View Details
Autoclave, Vertical, Stainless Steel, Nut Locking

Autoclave, Vertical, Stainless Steel, Nut Locking

Product Code : EL-A-12632

A vertical, floor-standing double-wall stainless steel autoclave with a nut-locking lid mechanism, rated 5 to 20 psi (roughly 109 to 126 degrees C) for higher-capacity steam sterilization.

View Details
Autoclave, Vertical, Double Walled, Radial Locking

Autoclave, Vertical, Double Walled, Radial Locking

Product Code : EL-A-12633

A vertical, floor-standing double-wall stainless steel autoclave with a radial-locking lid tightened by radial arms through a chrome-plated steering wheel, rated 5 to 20 psi (roughly 109 to 126 degrees C) for higher-capacity steam sterilization.

View Details
Autoclave, Triple Wall, Vertical, High Pressure

Autoclave, Triple Wall, Vertical, High Pressure

Product Code : EL-A-12634

A triple-wall, double-chamber vertical autoclave where the middle chamber acts as a steam stock jacket, rated 5 to 20 psi (roughly 109-126 degrees C) with a radial-arm locking lid and digital pressure, temperature, timer and low-water monitoring for high-

View Details
Autoclave, Horizontal, Cylindrical, Double Wall

Autoclave, Horizontal, Cylindrical, Double Wall

Product Code : EL-A-12635

The Autoclave, Horizontal, Cylindrical, Double Wall is a floor-mounted, double-wall steam sterilizer from EduScope India that runs at 1.2 to 1.5 Kg/cm2 (15 to 20 psi), giving a sterilizing temperature of approximately 121 to 126 degrees Celsius, with digi

View Details

Office Address

Works: Eduscope Smart Learning Solutions Pvt Ltd 112-A. First Floor, PP Trade Centre Netaji Subhash Palace, Pitampura
Delhi – 110034, India

[email protected]